Test result
Full Source Content
Full test source text copied onto the page for customer review.
Page 1
Preliminary Results Only (may be subject to change) Certificate of Analysis 47-2854223 520 South 850 East, Suite B3 Lehi, UT 84043 801-847-7722 www.analyticalresource.com info@yourqualitylab.com Client Information Sample Information ARL ID: 669207 Date Received: 4/25/2023 Date Tested: 5/17/2023 Description: 10 ppm SilverCeuticals Liquid SilverCeuticals Inc 4699 Wasatch Drive Highland, UT 84003 USA 801-361-5900 Specification UOM Method Results Analysis Lab ID † MDL / LOQ Results 1 USP 51 PET: Custom USP <51> Note 1 1 Organism: Candida auris CDC B11903 1 PET Suitability: C. auris USP <51> NLT 50% Saline Control Suitable Pass/Fail 1 Initial Concentration: C. auris USP <51> 1.4 x 10 5 cfu's/g 1 15 Minute Counts: C. auris USP <51> Record Only 200 10
cfu's/g 1 30 Minute Counts: C. auris USP <51> Record Only < 10 10 cfu's/g 1 Hour 1 Counts: C. auris USP <51> Record Only < 10 10 cfu's/g 1 Hour 4 Counts: C. auris USP <51> Record Only < 10 10 cfu's/g 1 Day 1 Counts: C. auris USP <51> Record Only < 10 10 cfu's/g 1 15 Minute Log Reduction: C. auris USP <51> Record Only 2.8 0.1 Log Reduction 1 30 Minute Log Reduction: C. auris USP <51> Record Only > 4.1 0.1 Log Reduction 1 Hour 1 Log Reduction: C. auris USP <51> Record Only > 4.1 0.1 Log Reduction 1 Hour 4 Log Reduction: C. auris USP <51> Record Only > 4.1 0.1 Log Reduction 1 Day 1 Log Reduction: C. auris USP <51> Record Only > 4.1 0.1 Log Reduction Notes: 1. Plating Method Suitable at 1:10 in TSB if "Suitable", 1:100 in TSB if "*Suitable", 1:1,000 in
TSB if "**Suitable", or other conditions if "†Suitable" (see linked note). Released by: Spencer Ashby experience • professionalism • value Form: arlcoa031201a Report: 669207 Printed on: 5/17/2023 4:51:26 PM Page 1 of 2 This Certificate of Analysis represents data only for the sample provided. It does not constitute a guarantee of quality for the entire production lot. Date Released: 5/17/2023
Page 2
ARL ID: 669207 Description: 10 ppm SilverCeuticals Liquid Lot: Serving Size: Specification UOM Method Results Analysis Lab ID † MDL / LOQ Results † Method Detection Limit (MDL) : In microbiological testing, this is the minimum level of growth that can be detected with confidence. If a result is reported as "None Detected", it means any visible growth was below this limit. † Limit of Quantitation (LOQ) : In analytical chemistry testing, this is the minimum level of the desired analyte that can be quantified with confidence. If a result is reported as less than LOQ, it means any detected amount was too small to report an exact number. Under accreditation number 77504, ARL is an ISO/IEC 17025:2017 Accredited Laboratory. Uncertainty data for ISO-scoped
methods is available upon request. Certificate and scope are also available upon request. Released by: Spencer Ashby experience • professionalism • value Form: arlcoa031201a Report: 669207 Printed on: 5/17/2023 4:51:26 PM Page 2 of 2 This Certificate of Analysis represents data only for the sample provided. It does not constitute a guarantee of quality for the entire production lot. Date Released: 5/17/2023